Temperature and humidity control module switch, automatic constant temperature and humidity control instrument panel

parameters:

  • Name: Temperature / Humidity Controller
  • Model: XY-TR01
  • Humidity range: 0%~100%RH
  • Temperature range: -20~60 degrees
  • Control accuracy: 0.1 degrees / 0.1% RH
  • Detection probe: integrated sensor
  • Output type: relay output
  • Output capacity: up to 10A
  • Size: 57*60*20mm

Product Features:

Temperature function:

  1.  the working mode is automatically recognized, The system automatically recognizes the operating mode based on the start/stop temperature

Start temperature > stop temperature, cooling mode 'C'; start temperature < stop temperature, heating mode 'H'.

  

Cooling mode

When the temperature > start temperature is detected, the relay is turned on, the red indicator light is on, and the refrigeration device starts to work;

When the temperature is detected <starting temperature, the relay is turned off, the red indicator light is off, and the cooling device stops working;

  

Heating mode

When the temperature is detected <starting temperature, the relay is turned on, the red indicator light is on, and the heating device starts to work;

When the temperature > start temperature is detected, the relay is turned off, the red indicator light is off, and the heating device stops working;

  

Temperature correction function OFE (-10 ~ 10 degrees)

If the system works for a long time, there may be deviations and it is difficult to correct this power;

Actual temperature = measured temperature + calibration value

How to set the start/stop temperature:

1. In the running interface, long press the 'TM+' button for more than 3s to enter the startup temperature setting interface. The test can modify the parameters through the TM+/TM- key. After the parameter modification is completed, wait for 6s to automatically exit and save;

2. In the running interface, long press the 'TM-' button for more than 3s to enter the stop temperature setting interface. The test can modify the parameters through the TM+/TM- key. After the parameter modification is completed, wait for 6s to automatically exit and save.

Humidity function:

1, the working mode is automatically recognized

The system automatically recognizes the working mode according to the starting humidity/stop humidity.

Start humidity > stop humidity, dehumidification mode 'D'; start humidity < stop humidity, humidification mode 'E'

Dehumidification mode

When detecting humidity > starting humidity, the relay is turned on, the green indicator light is on, and the dehumidification device starts to work;

When the detection temperature <start humidity, the relay is turned off, the green indicator light is off, and the dehumidification device stops working;

Humidification mode:

When the humidity is detected <starting humidity, the relay is turned on, the green indicator light is on, and the humidifying device starts to work;

When detecting humidity > starting humidity, the relay is turned off, the green indicator light is off, and the humidifying device stops working;

4, humidity correction function RH (-10~10 degrees)

If the system works for a long time, there may be deviations and it is difficult to correct this power;

Actual humidity = measured humidity + calibration value

How to set the start/stop humidity:

1. In the running interface, press and hold the 'RH+' button for more than 3s to enter the startup humidity setting interface. The test can modify the parameters through the RH+/RH- key. After the parameter modification is completed, wait for 6s to automatically exit and save.

2. In the running interface, press and hold the 'RH-' button for more than 3s to enter the stop humidity setting interface. The test can modify the parameters through the RH+/RH- key. After the parameter modification is completed, wait for 6s to automatically exit and save.